Flowback & Testing Services

Denmon's offers competent operators to flow back, clean up and test oil & gas wells. our inventory includes:

High Pressure Horizontal Separator

1422 psi working pressure 20" X 7'6" 3 phase
Gas Capacity 15 MMCFD
Liquid Capacity 3000 bpd, 180 barrels an hour
1" liquid dump valves with 3/4" trim
3" Simplex meter tube (2" bypass) with 3 pen Barton Meter
1" Halliburton Turbine Meters on both liquid dump lines
2" Gas outlet back pressure control valve
Year Manufactured 2002
NACE rated ASME Coded

High Pressure Manifold and Flowline (2")

15,000 psi working pressure tested 22,500 psi
Dual chokes 3/4" Adjustable or Positive
1502 Unions with Viton inserts
150' iron & 4 chicksans
Electronic pressure Gauge 10,000 psi

Indirect Line Heator

2" coils 6,500 psi working pressure with Thornhill
Craver Adjustable choke
Burner rated 750,000 btu/hour

Jumbo Horizontal Separator

8' X 12' (130 bbl) 150 psi working pressure 2 phase
2" Halliburton Turbine meter on liquid dump
4" Simplex Meter Tube with 3 pen Barton Meter
Year Manufactured 1995
NACE rated ASME Coded

Mud Gas Separators
5' X 10' vertical 2 phase
6" inlet, 6' gas and liquid outlets
Gravity dump liquid
Tested at 150 psi
Related piping and fittings
 
 
 
 
"Safety is our Business"
12872 Hwy. 155 South, Bldg. 18 • Tyler, Texas 75703 • (903)-561-5706